Benefits
- Advanced DSP control technology delivers accurate data.
- Built-in smart MPPTs to enhance overall efficiency.
- Up to 96% high conversion efficiency.
- IP 65 protection for outdoor and harsh environment.
- Industrial-grade components used for robust operation.
- High performance redundancy cooling system.
- Option parallel operation.
- Option parallel operation.
- 1-year product warranty.
Specification
Model | FA-ON-INV-10KVA | FA-ON-INV-12.5KVA | FA-ON-INV-15KVA | FA-ON-INV-17KVA | FA-ON-INV-20KVA | FA-ON-INV-30KVA |
Capacity | 10KW | 12.5KW | 15KW | 17KW | 20KW | 30KW |
DC INPUT | ||||||
Max. DC power | 12 KW | 14KW | 17KW | 19KW | 22KW | 33KW |
Max. DC voltage | 900VDC | 1000VDC | ||||
Operating Voltage Range | 200~850Vdc | – | ||||
MPPT voltage range | 250~850Vdc (Rated voltage 580Vdc) | |||||
Number of MPPT trackers | 3 | |||||
Max. input current per MPPT Tracker | 12A/12A/12A | 17A/17A/17A | 26A/26A/26A | |||
AC OUTPUT | ||||||
Rated output power | 10KW | 12.5KW | 15KW | 17KW | 20KW | 30KW |
Rated output voltage | 400VAC | |||||
AC output topology | Hardwire 5-wire (3 Ph+N+G) | |||||
Output voltage range | 400Vac±20% (adjustable) | |||||
Grid frequency range | 50 / 60Hz(±5Hz),(adjustable) | |||||
Rated AC output current | 15.2A | 18.9A | 22.9A | 25.8A | 29.0A | 44.0A |
Max. output current | 17A | 20.0A | 24.0A | 27.0A | 30.0A | 48.0A |
Power factor | 1(Lagging0.9~Leading0.9)(adjustable) | |||||
THDI | <3% | |||||
PROTECTION | ||||||
DC Reserve-Polarity Protection | Yes | |||||
Ground Fault Monitoring | Yes | |||||
Grid Monitoring | Yes | |||||
AC Short Circuit Protection | Yes | |||||
Over Current Protection | Yes | |||||
SYSTEM FEATURES | ||||||
Max. efficiency | >98.0% | >98.0% | >98.1% | >98.1% | >98.2% | >98.2% |
Euro efficiency | >97.5% | >97.5% | >97.6% | >97.6% | >97.7% | >97.8% |
MPPT efficiency | 99.90% | |||||
Cooling | Forced air cooling | |||||
Communication interface | RS485 , external Ethernet (optional) | |||||
ENVIRONMETAL | ||||||
Operating temperature | -20°C~60°C(optional) | |||||
Humidity range | 0~95% (non-condensing) | |||||
Altitude | <2000m | |||||
Noise level | <40dB | <60dB | ||||
PHYSICAL | ||||||
Dimension W×H×D (mm) | 506×670×210 | 522×690×210 | 600×800×250 | |||
Net weight (kg) | 44 | 50 | 65 |
Specification
Model | FA-ON-INV-50KVA-3PH | FA-ON-INV-100KVA-3PH | FA-ON-INV-250KVA-3PH | FA-ON-INV-500KVA-3PH | FA-ON-INV-630KVA-3PH | FA-ON-INV-750KVA-3PH | FA-ON-INV-1000KVA-3PH | FA-ON-INV-1250KVA-3PH |
Capacity | 50KVA | 100KVA | 250KVA | 500KVA | 630KVA | 750KVA | 1000KVA | 1250KVA |
DC INPUT | ||||||||
Max. DC power | 55 KW | 110 KW | 275 KW | 550 KW | 690 KW | 825KW | 1000KW | 1562KW |
Max. DC voltage | 900VDC | 1000VDC | 1000VDC | |||||
Operating Voltage Range | ||||||||
MPPT voltage range | 450~850Vdc (Rated voltage 576Vdc) | 580~850Vdc | ||||||
Number of MPPT trackers | 1 | 10 | 16 | 20 | ||||
Max. input current per MPPT Tracker | 120A | 240A | 600A | 1200A | 1440A | 1500A | 1935A | 2420A |
AC OUTPUT | ||||||||
Rated output power | 50KW | 100KW | 250KW | 500KW | 630KW | 750KW | 1000KW | 1250KW |
Rated output voltage | ||||||||
AC output topology | ||||||||
Output voltage range | (1±15%)*Normal AC Voltage (adjustable ±5%,±10%,±15%,±20%) | |||||||
Grid frequency range | 50 / 60Hz(±4.5Hz)(adjustable) | |||||||
Rated AC output current | 72A | 144A | 361A | 722A | 909A | 1237A | 1444A | 1804A |
Max. output current | 79A | 158A | 397A | 794A | 1000A | 1360A | 1588A | 1984A |
Power factor | ||||||||
THDI | ||||||||
PROTECTION | ||||||||
DC Reserve-Polarity Protection | yes | |||||||
Ground Fault Monitoring | yes | |||||||
Grid Monitoring | yes | |||||||
AC Short Circuit Protection | yes | |||||||
Over Current Protection | yes | |||||||
SYSTEM FEATURES | ||||||||
Max. efficiency | 97.00% | 97.50% | 97.60% | 98.10% | 98.10% | 99.00% | ||
Euro efficiency | 96.50% | 97.00% | 97.00% | 97.60% | 97.60% | 98.70% | ||
MPPT efficiency | 99.90% | |||||||
Cooling | Forced air cooling | |||||||
Communication interface | RS485 , external Ethernet (optional) | |||||||
ENVIRONMETAL | ||||||||
Operating temperature | -40°C~55°C(optional) | |||||||
Humidity range | 0~95% (non-condensing) | |||||||
Altitude | 3000m | |||||||
Noise level | <58dB | <60dB | <58dB | <60dB | ||||
PHYSICAL | ||||||||
Dimension W×H×D (mm) | 600×1600×945 | 835×1850×945 | 1200×1850×945 | 1600×1850×945 | ||||
Net weight (kg) | 520 | 900 | 1470 | 2800 | 3150 |