12V STATIC INVERTER (750VA – 1500VA)

Benefits

  • Advance i-DSP technology delivers a pure sine wave output suitable for electrical and electronic loads.
  • Wide operation voltage range, charges battery at low voltage, increased battery life.
  • More back-up time achieved through intelligent smart design of transformer suing primary copper.
  • 100% copper design for long life and it delivers 15A charging current for quick charging of battery.
  • Charging technique for superior performance of battery.
  • Intelligent program reduces grid power consumption for recharging of battery.
  • Enhanced output voltage for battery performance of TV, Lights, Fans, Computers, etc.

Specification

MODEL NUMBER FA-INV-12V-750VA FA-INV-12V-850VA FA-INV-12V-1100VA FA-INV-12V-1500VA
Capacity 750VA/490W 850VA/620W 1100VA/730W 1500VA/1000W
NARROW MODE
Mains undervoltage cutoff /recovery 180 V / 190 V
Mains overvoltage cutoff /recovery 265 V / 255 V
Battery charging voltage 180 VAC to 265 VAC
Changeover time ≤ 10 milliseconds
Output voltage (no load) 230 V
WIDE MODE
Mains undervoltage cutoff /recovery 100 V / 110 V
Mains overvoltage cutoff /recovery 295 V / 285 V
Battery charging voltage 100 VAC to 295 VAC
Changeover time ≤ 20 milliseconds
Output voltage (no load) 230 V
BATTERY
Quick charge current 14A
Normal charge current 10A
Boost charge voltage 14.5V
Float charge voltage 13.8V
Low battery cutoff point 10.4V
Number of batteries 1 *12VDC
Recommended battery 65 AH to 200 AH
Charge method Constant current ,followed by constant voltage
Output waveform Pure sine wave
Output frequency (UPS mode) 50 HZ
Efficiency ≥80%
Operation temperature 0 to 45°C
LED indicators Mains,charging,UPS,low battery, overload
Audible alarm Low battery,overload,short circuit
PROTECTIONS
Overload 105% load on UPS (auto reset within 5 re-tries)
overcharge Control battery voltage and current through software
Short circuit MCB Tripe in Main mode and UPS gets shut down in Back-up mode
Thermal UPS get shut down when temperature reaches to 95 C at inside UPS
Battery reverse polarity DC fuse on PMB will fail when battery terminals connected wrongly
Battery deep discharge UPS will shut down when battery voltage reaches to 10.4V (Per battery)
PACKING INFORMATION
Net weight 8.4kg 9 kg 12.8 kg 16.5 kg
Gross weight 9 kg 9.8 kg 12.9 kg 17.2 kg
Dimensions 32.5 x 32.5 x 17.0 cm 32.5 x 32.5 x 17.0 cm 38.0 x 35.8 x 18.0 cm 38.0 x 35.5 x 18.0 cm