Benefits
- Pure Sine Wave Output Suitable for Electrical and Electronics gadgets
- Can support machines with high starting current
- 100% Copper Transformer design for long life and it delivers high charging current for quick charging of battery
- Multi Stage Charging technique for superior performance of battery
- High Charging current of 15A for faster recharging of battery
- Wide Operating Voltage range, charges battery even at low voltage, increases battery life
- Less Change-over time suitable to use computer, IT Peripherals etc..
- Enhanced output voltage for better performance of loads.
- LCD display for better user interface.
Specification
MODEL NUMBER | FA-INV-48V- 2500VA |
FA-INV-48V- 3500VA |
FA-INV-48V- 5000VA |
FA-INV-120V- 7500VA |
FA-INV-180V- 10KVA |
Capacity | 2500VA/2200W | 3500VA/2860W | 5000VA/4400W | 7500VA/6600W | 10KVA/8.8KW |
NARROW MODE | |||||
Mains undervoltage cutoff /recovery | 180 V / 190 V | ||||
Mains overvoltage cutoff /recovery | 265 V / 255 V | ||||
Battery charging voltage | 180 VAC to 265 VAC | ||||
Changeover time | ≤ 10 milliseconds | ||||
Output voltage (no load) | 220 V | ||||
WIDE MODE | |||||
Mains undervoltage cutoff /recovery | 125 V / 135 V | ||||
Mains overvoltage cutoff /recovery | 295 V / 285 V | ||||
Battery charging voltage | 100 VAC to 295 VAC | ||||
Changeover time | ≤ 50 milliseconds | ||||
Output voltage (no load) | 220 V | ||||
BATTERY | |||||
Quick charge current | 15A | ||||
Normal charge current | 15A | ||||
Boost charge voltage | 14.5V/Batt | ||||
Float charge voltage | 13.6V/Batt | ||||
Low battery cutoff point | 10.4V/Batt | ||||
input voltage | 48V | 48V | 48V | 120v | 180v |
Number of batteries | 4 *12VDC | 10 *12VDC | 15 *12VDC | ||
Recommended battery | 65 AH to 200 AH | ||||
Charge method | Constant current ,followed by constant voltage | ||||
Output waveform | Pure sine wave | ||||
Output frequency (UPS mode) | 50 HZ | ||||
Efficiency | ≥80% | ||||
Operation temperature | 0 to 50°C | ||||
LCD indicators | Mains,charging,UPS,low battery, overload,Short circuit | ||||
Audible alarm | Low battery,Overload,short circuit | ||||
PROTECTIONS | |||||
Overload | 105% load on UPS (auto reset within 5 re-tries) | ||||
Overcharge | Control battery voltage and current through software | ||||
Short circuit | Shut down (UPS mode),MCB trip (AC mode) | ||||
Thermal | shut down at 93°C | ||||
Battery reverse polarity | DC fuse on PMB will fail when battery terminals connected wrongly | ||||
Battery deep discharge | UPS will shut down when battery voltage reaches to 10.4V (per battery) | ||||
PACKING INFORMATION | |||||
Net weight | 29 kg | 32 kg | 54KG | 78KG | 89KG |
Dimensions | 31.0 x 29.0 x 45.0 cm | 31.0 x 29.0 x 45.0 cm | 55.0 x 35.0 x 65.0 cm | 55.0 x 35.0 x 65.0 cm | 55.0 x 35.0 x 65.0 cm |