1PH-ONLINE UPS PI SERIES(1KVA-10KVA)

Benefits

  • Wide Input voltage range (110V-300V).
  • Adjustable output voltage (220V-240V).
  • 50/60 Hz frequency converter mode.
  • Input power factor correction.
  • True online double-conversion technology with high power density, utility frequency independence.
  • Three segment charging mode to increase battery service life, optimize recharge time.
  • Selectable High Efficiency mode of operation.
  • Cold start function to startup the UPS without utility.
  • Parallel capability up to 3 units (for 6KVA & 10KVA).
  • Emergency, shutdown control through the remote emergency power-off (EPO) port.
  • Power shedding function may turn off uncritical load in battery backup to make longer backup time for critical load.
  • Rack-mount design.

Specification

MODEL FA-UPSX-36V-
1KVA-1PH
FA-UPSX-36V-
1.5KVA-1PH
FA-UPSX-48V-
2KVA-1PH
FA-UPSX-72V-
3KVA-1PH
FA-UPSX-240V-
6KVA-1PH
FA-UPSX-240V-
10KVA-1PH
PHASE 1 phase in/ 1 phase out
Capacity(VA/Watts) 1000 VA/1000 W 1500 VA/1500 W 2000 VA/2000 W 3000 VA/3000 W 6000 VA/6000 W 10000 VA/10000 W
INPUT
Input Voltage Range 160-300 VAC ± 5 % at 100% load 110-300 VAC ± 5% at 50% load 160-300 VAC ± 5 % at 100% load 110-300 VAC ± 5% at 50% load 160-300 VAC ± 5 % at 100% load 110-300 VAC ± 5% at 50% load 160-300 VAC ± 5 % at 100% load 110-300 VAC ± 5% at 50% load 140-300 VAC @ 60~80 % load; 110-300 VAC @ 0~60% load;
176-300 VAC @ 80~100 % load
140-300 VAC @ 60~80 % load; 110-300 VAC @ 0~60% load;
176-300 VAC @ 80~100 % load
Frequency range 40 Hz ~ 70 Hz 41 Hz ~ 70 Hz 42 Hz ~ 70 Hz 43 Hz ~ 70 Hz 49 ~54 Hz or 56~64 Hz 50 ~54 Hz or 56~64 Hz
Power factor ≥ 0.99 (100% Load)
OUTPUT
Output voltage 200/208/220/230/240 VAC 200/208/220/230/240 VAC 200/208/220/230/240 VAC 200/208/220/230/240 VAC 208/220/230/240 VAC 208/220/230/240 VAC
AC Voltage Regulation (Batt.
Mode)
± 1%
Transfer Time AC to DC Zero Zero Zero Zero Zero Zero
Transfer Time Inverter to
Bypass
4 ms (Typical) 5 ms (Typical) 6 ms (Typical) 7 ms (Typical) Zero Zero
Waveform (Batt. Mode) Pure Sine wave
EFFICIENCY
Line Mode ≥ 91% @ battery fully charged
ECO Mode ≥ 96% @ battery fully charged
Battery Mode ≥ 90% ≥ 90% ≥ 90% ≥ 90% 91% 91%
BATTERY
Stander Battery type 12V/7 Ah or 12V/ 9 Ah
External Battery type Depending on applications (65AH – 200AH)
Numbers 3 3 4 6 20 20
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current 200/208/220/230/240 VAC Models: default 2A, max. 12A default 1A, max. 4A adjustable default 1A, max. 4A adjustable
Charging Voltage 41.1 VDC ±1% 41.1 VDC ±1% 54.8 VDC ±1% 82.1 VDC ±1% 273 VDC ±1%
ALARM
Battery Mode Sounding every 5 seconds
Low Battery Sounding every 2 seconds
Overload Sounding every second
Fault Continuously sounding
ENVIRONMENTAL
Humidity 20-90% RH @ 0- 45°C (Non-condensing)
Noise Level Less than 50dBA@1 Meter
PHYSICAL
Dimension D*W*H (mm) 410 x 438 x 88 410 x 438 x 88 510 x 438 x 88 630 x 438 x 88 600x438x88